How drugs are made?Idea to market: modality, dosage form, stage, functions, GxP
← Back to map
Map › Axis 2: Dosage form and route

Axis 2: Dosage form and route

How the product reaches the patient, how fast it releases, and where it acts.

Open this in the interactive map →

Oral Tablets, capsules, liquids; the default for small molecules

Tablets, capsules, liquids; the default for small molecules

What it covers

Swallowed and absorbed through the gut. Tablets (immediate release, modified release, orally disintegrating), capsules (hard and soft), oral solutions, suspensions and powders for reconstitution. Convenient, cheap to make, no sterility requirement, but the drug must survive acid and enzymes, dissolve, cross the gut wall and survive first-pass metabolism in the liver.

CMC and formulation

  • Biopharmaceutics Classification System (BCS): solubility and permeability decide whether formulation can help (class II needs solubility enhancement; class III and IV are hard)
  • Solid form (polymorph, salt), particle size and excipients determine dissolution
  • Manufacturing: blending, granulation (wet or dry), compression, coating; continuous manufacturing increasingly used (ICH Q13)
  • Food effect and drug interaction studies define the label
  • Paediatric forms (mini-tablets, liquids, taste masking) are separate developments

Analytical picture

  • Dissolution testing is the critical link to in vivo performance and the main comparability and bioequivalence tool
  • Content uniformity, assay, related substances, water content
  • Stability with humidity as a major stressor
Relation to modality: Realistic for small molecules and a few cyclic or enhanced peptides. Not realistic for proteins, antibodies, nucleic acids or cells for systemic effect, because they are digested or not absorbed.

Parenteral (injection and infusion) IV, SC, IM and specialised routes; sterile products

IV, SC, IM and specialised routes; sterile products

What it covers

Delivered by injection or infusion, bypassing the gut. Intravenous (bolus or infusion, immediate systemic exposure), subcutaneous (self-administration, slower absorption, volume limits of about 1 to 2 mL unless enhanced), intramuscular (vaccines, depots), and specialised routes such as intrathecal (into cerebrospinal fluid), intravitreal (into the eye), intra-articular and intratumoural. Presentations: vials (liquid or lyophilised), prefilled syringes, cartridges in pens, autoinjectors, infusion bags.

CMC and formulation

  • Sterility and endotoxin control; aseptic processing (EU Annex 1, 2022 revision) or terminal sterilisation where the molecule tolerates it
  • Container closure integrity, extractables and leachables from stoppers, syringes and silicone oil
  • Solubility and stability in solution; lyophilisation for unstable molecules; cosolvents, cyclodextrins, liposomes, lipid nanoparticles
  • Device integration turns the product into a combination product with design controls and human factors work
  • Cold chain for most biologics; particulates and aggregation are recurring quality issues

Analytical picture

  • Sterility, bacterial endotoxin, subvisible and visible particulates, container closure integrity testing
  • Assay, purity, osmolality, pH, reconstitution time for lyophilisates
  • Functional device tests (injection force, dose accuracy)
Relation to modality: The universal route: every modality can be given parenterally, and for biologics, nucleic acids and cell therapies it is essentially the only realistic route. The word "parenteral" therefore tells you nothing about what the molecule is.

Inhaled Lung delivery for local or systemic effect; device-defined products

Lung delivery for local or systemic effect; device-defined products

What it covers

Aerosols delivered to the airways. Pressurised metered dose inhalers (MDI), dry powder inhalers (DPI), nebulisers (solutions or suspensions aerosolised by a machine) and soft mist inhalers. Mostly for local action in asthma and COPD; occasionally systemic (inhaled insulin). Deposition depends on aerodynamic particle size, ideally 1 to 5 micrometres.

CMC and formulation

  • The device is inseparable from the product; changing it changes the dose delivered
  • Particle engineering: micronisation, spray drying, carrier lactose blends for DPIs
  • Propellant transitions (HFA, and now low global-warming-potential propellants) force reformulation
  • Extractables from valves and canisters; moisture protection for DPIs
  • Generic inhalers are among the hardest complex generics

Analytical picture

  • Aerodynamic particle size distribution by cascade impaction is the defining test
  • Delivered dose uniformity through the life of the device, fine particle dose
  • Spray pattern and plume geometry for sprays; nebuliser output rate
Relation to modality: Mainly small molecules. A few proteins (nebulised dornase alfa) and peptides (inhaled insulin) exist; inhaled nucleic acids and gene therapies are in development but aerosolisation stresses large molecules and nanoparticles.

Topical and transdermal Skin as target or as gateway

Skin as target or as gateway

What it covers

Topical products (creams, ointments, gels, foams, solutions) act locally on or in the skin, with minimal systemic exposure intended. Transdermal systems (patches, gels) use the skin as a route to systemic circulation for potent, low-dose, lipophilic molecules such as nicotine, fentanyl, estradiol or buprenorphine. Semisolids are structured systems whose microstructure affects performance.

CMC and formulation

  • Skin barrier limits permeation to small, lipophilic molecules; enhancers and microneedles push the boundary
  • Semisolid microstructure (globule size, rheology, phase behaviour) is a quality attribute in its own right
  • Patches: adhesive performance, drug crystallisation in the matrix, dose dumping risk with heat
  • Local tolerance and sensitisation studies

Analytical picture

  • In vitro release testing (IVRT) and in vitro permeation testing (IVPT) using human skin as performance tests
  • Rheology, globule size distribution, pH, assay and preservative content
  • EMA guideline on quality and equivalence of locally applied, locally acting cutaneous products (2024) and FDA product-specific guidances set the expectations for generics
Relation to modality: Small molecules dominate. A topical gene therapy (HSV-1 vector gel for epidermolysis bullosa) shows that vectors can work where the target is the skin itself. Proteins and peptides do not cross intact skin usefully; some are applied to wounds or mucosa.

Other routes Nasal, ophthalmic, rectal, vaginal, buccal, implants

Nasal, ophthalmic, rectal, vaginal, buccal, implants

What it covers

Nasal sprays (local for rhinitis, systemic for peptides and rescue medicines such as naloxone, and a route to the brain under investigation). Ophthalmic drops, ointments, intravitreal implants. Rectal and vaginal forms (suppositories, rings). Buccal and sublingual films and tablets that avoid first-pass metabolism. Implants and depots placed surgically or by injection that release for months to years.

CMC and formulation

  • Mucosal routes need preservative systems, isotonicity and pH control; ophthalmic products are sterile
  • Sprays and drops share device-dependence with inhalation products (droplet size, spray pattern)
  • Long-acting implants need release-controlling polymers and in vitro release methods that predict months of performance

Analytical picture

  • Sterility for ophthalmic; droplet size, spray content uniformity for nasal; in vitro release for implants and rings
  • Local irritation and tolerance
Relation to modality: Small molecules for most; peptides work nasally (desmopressin, calcitonin); a live attenuated influenza vaccine is intranasal; some cell and gene therapies are delivered by surgical routes (subretinal injection) that are routes in their own right.

Release rate: immediate, modified, depot How fast, and for how long, the dose is delivered

How fast, and for how long, the dose is delivered

What it covers

Immediate release: the dose is available as soon as the form disintegrates or is injected. Modified release covers extended (sustained) release that smooths peaks and reduces dosing frequency; delayed release (enteric coating) that protects acid-labile drugs or targets the intestine; and pulsatile release. Depot or long-acting injectables deliver a dose over weeks to months from microspheres, in situ forming gels, oil solutions, crystalline suspensions or implants, for example monthly to six-monthly leuprolide or paliperidone.

CMC and formulation

  • Release is engineered through polymer matrices, coatings, osmotic pumps or particle properties; small changes in excipients or process can change the release profile
  • Dose dumping (alcohol, heat) is a safety concern for extended-release opioids and patches
  • Long-acting injectables are complex generics requiring in vitro and in vivo release characterisation
  • For biologics, half-life extension is done to the molecule (Fc fusion, PEGylation, lipidation) rather than the formulation, although depot antibodies are being explored

Analytical picture

  • Discriminating dissolution or in vitro release methods, sometimes over days or weeks (accelerated methods with validation against real-time release)
  • In vitro in vivo correlation (IVIVC) when achievable
  • Release-profile comparability (f2 similarity factor) after changes
Relation to modality: Release engineering is largely a small-molecule and peptide discipline. Modality does not fix it: an oral tablet can be immediate or extended release; a subcutaneous injection can be a solution or a three-month depot.

Site of action: local vs systemic Where the drug must be, which decides what exposure means

Where the drug must be, which decides what exposure means

What it covers

Systemic products must reach the bloodstream and distribute to the target tissue; their dose is judged by plasma exposure (PK) and the route can be chosen for convenience. Locally acting products (inhaled bronchodilators, topical steroids, ophthalmic drops, intravitreal injections, intrathecal oligonucleotides) act at the site of administration; plasma levels are a safety measure, not an efficacy measure, and bioequivalence must be shown by other means.

CMC and formulation

  • Local action allows very small doses and can avoid systemic toxicity, but makes dose-response and equivalence harder to measure
  • Systemic delivery of large molecules almost always means injection; local delivery can sometimes open a route that would fail systemically (inhaled proteins, topical vectors)
  • Targeting (GalNAc to liver, antibodies to tumour antigens, AAV serotypes to tissues) is the molecular version of site selection

Analytical picture

  • Performance tests for locally acting products replace PK: dissolution or release, particle size, permeation, pharmacodynamic endpoints
  • Tissue distribution and clearance studies for local routes
Relation to modality: Independent of modality: a small molecule can be local (inhaled) or systemic (oral); a biologic can be systemic (IV antibody) or local (intravitreal antibody); a gene therapy can be systemic (IV AAV) or local (subretinal AAV).

Practitioner reference, not regulatory advice. US framing uses FDA terminology; EU framing uses EMA and EudraLex terminology. Durations, costs and attrition are indicative. © 2026 Haris Khan. All rights reserved.