Map › Who does what at each stage
Who does what at each stage
What each function does at each stage of drug development: discovery, CMC, analytical, clinical, regulatory, quality, safety, manufacturing and systems.
Open this in the interactive map →
Discovery
| Stage | What this function is doing |
|---|---|
| Discovery | LeadingTarget ID, hit finding, lead optimisationOwns the programme until candidate selection. Delivers the molecule, the mechanism data and the first view of developability. Informatics: ELN, compound registration, screening databases, cheminformatics or antibody sequence databases. |
| Preclinical | SupportingHandover, backup compoundsSupports IND-enabling work with mechanism questions and biomarker assays; progresses backup series in case the lead fails on toxicology. |
| Phase 1 | SupportingBiomarkers, mechanism supportTranslational biology moves biomarker assays into the clinic; discovery proper has moved on to the next target. |
| Phase 2 | Not activeLittle involvement beyond translational questions raised by clinical data. |
| Phase 3 | Not activeNot active. |
| Submission | Not activeNot active. |
| Approval and launch | Not activeNot active. |
| Post-market | SupportingNext-generation programmesFollow-on molecules and lifecycle candidates (improved PK, new mechanism combinations) start here. |
CMC / Process
| Stage | What this function is doing |
|---|---|
| Discovery | SupportingPreformulation, route scouting, developabilityEarly CMC assesses whether the candidate can be made and formulated: solubility, solid form, stability, synthetic route or expression yield. Prevents selecting a molecule that cannot be developed. |
| Preclinical | ActiveProcess definition, first GMP batch, FIH formulationDefines a route or process that can make GMP material at the required scale, chooses the FIH formulation, and manufactures the first clinical batch, usually at a CDMO for smaller companies. |
| Phase 1 | ActiveScale-up, process developmentImproves yield and robustness; scales to supply Phase 2; begins to understand critical process parameters. For biologics, cell line and process changes here trigger comparability. |
| Phase 2 | ActiveProcess characterisation, commercial formulation decisionDesign of experiments to define the design space and control strategy (ICH Q8, Q11). Commits to the commercial formulation, presentation, site and scale before Phase 3 starts. |
| Phase 3 | LeadingProcess validation (PPQ), tech transferTransfers the process to the commercial site, runs process performance qualification batches, and writes the control strategy and Module 3.2.S.2 and 3.2.P.3 content. Critical path to filing. |
| Submission | LeadingModule 3 authoring, agency questions, PAIAnswers CMC questions, supports the pre-approval inspection, and completes any remaining validation commitments. |
| Approval and launch | ActiveLaunch supply, commercial handoverHands the process to manufacturing and MSAT; supports early commercial batches and any issues in the first campaigns. |
| Post-market | ActivePost-approval changes, second sourcing, CPVManages process improvements, site and supplier changes through comparability and variations; supports continued process verification and cost-of-goods reduction. |
Analytical
| Stage | What this function is doing |
|---|---|
| Discovery | SupportingResearch-grade characterisation, fit-for-purpose methodsIdentity and purity by LC-MS, NMR, HPLC for small molecules; SEC, SDS-PAGE or CE, mass spectrometry for proteins. Methods are not validated; the aim is to know what the molecule is and to rank candidates on developability. Reference material is research grade. Systems: ELN, instrument software, often no CDS validation. |
| Preclinical | ActiveMethod development, qualification, GMP release of first batch, stability startDevelops the release and stability methods for DS and DP, qualifies them (phase-appropriate: specificity, linearity, precision at minimum), establishes the first reference standard, sets preliminary specifications (ICH Q6A or Q6B logic), and starts formal stability under ICH Q1 conditions. Also supports GLP toxicology with validated dose-formulation analysis. Bioanalytical PK methods are developed for tox and the clinic. First point at which CDS and LIMS records become GxP records. |
| Phase 1 | ActivePhase-appropriate validation, impurity and degradant ID, bioanalytical validation (ICH M10)Forced degradation studies identify degradants and prove the stability-indicating power of the methods. Bioanalytical methods for human PK are fully validated. Method robustness improves as batches are made at larger scale. Immunogenicity (ADA) assays for biologics are validated in tiers. Extractables and leachables screening begins for parenteral packaging. |
| Phase 2 | ActiveMethod optimisation, potency assay, specification refinement, comparability testingMethods are made ready for full validation and transfer: optimised, robustness studied (ICH Q14 encourages a documented analytical target profile and risk-based development). Potency bioassays for biologics move from relative binding to cell-based formats and are validated. Every process change is characterised through side-by-side comparability testing. Specifications tighten as batch history accumulates. |
| Phase 3 | LeadingFull validation (ICH Q2(R2)), method transfer, registration stability, specification justificationFull validation of every release and stability method, method transfer into commercial QC laboratories (and CMO labs), registration stability on PPQ or registration batches, and the justification of specifications from clinical experience and batch data. Elemental impurities (ICH Q3D), residual solvents (Q3C), mutagenic impurities (M7), nitrosamines and extractables and leachables assessments are completed. The analytical package is a major share of Module 3. |
| Submission | LeadingModule 3.2.S.4 and 3.2.P.5 authoring, CMC questions, PAI readiness of QC labsWrites and defends the analytical sections: procedures, validation, batch analyses, characterisation of impurities, justification of specifications, reference standards. Responds to agency questions, often about method suitability or specification limits. Prepares QC labs for inspection: data integrity of CDS, LIMS, audit trails, OOS procedures. |
| Approval and launch | ActiveCommercial QC release, stability commitment, method performance monitoringRoutine release and stability testing by QC under GMP; analytical development retreats to a support role. Stability commitment batches (first three commercial batches) are enrolled. Method performance is trended, and reference standard qualification programmes begin. |
| Post-market | ActiveOngoing stability, OOS/OOT, method lifecycle (Q14), method changes and variations, APR trendsInvestigates out-of-specification and out-of-trend results, manages method changes and technology replacements (for example moving from HPLC to UPLC, or replacing an animal-based potency assay), supports comparability for process changes, and feeds trend data into annual product reviews. Lab systems (LIMS, CDS, ELN, SDMS) are in a validated state under change control, with periodic review. |
Clinical
| Stage | What this function is doing |
|---|---|
| Discovery | Not activeTPP inputProvides the clinical view of the target product profile and unmet need; no trials yet. |
| Preclinical | SupportingFIH protocol, IB, site selectionWrites the first protocol and Investigator Brochure, selects a Phase 1 unit, and prepares informed consent and ethics submissions. |
| Phase 1 | LeadingSAD/MAD, PK, early PDRuns the first-in-human study; medical monitoring and dose escalation decisions. Clinical pharmacology models exposure. |
| Phase 2 | LeadingProof of concept, dose findingRuns the Phase 2 programme, refines endpoints and patient selection, and designs Phase 3 with biostatistics. |
| Phase 3 | LeadingPivotal trialsExecutes the pivotal programme at scale: site management, monitoring, data management, database lock and CSRs. Critical path to filing. |
| Submission | ActiveCSRs, integrated summaries, agency responsesCompletes clinical modules, answers clinical questions, prepares for advisory committee. |
| Approval and launch | SupportingLabel support, Phase 4 planningSupports launch with clinical data interpretation and starts post-marketing studies. |
| Post-market | ActivePhase 4, new indications, paediatric studiesRuns commitments and lifecycle trials; new indication programmes restart the clinical cycle. |
Regulatory
| Stage | What this function is doing |
|---|---|
| Discovery | Not activeStrategy inputAdvises on modality classification, likely route (NDA vs BLA), designations worth pursuing, and precedent. |
| Preclinical | ActivePre-IND or scientific advice, IND/CTALeads the first agency interaction and authors and submits the IND or CTA. Regulatory CMC reviews the IMPD. |
| Phase 1 | SupportingAmendments, DSUR, annual reportsMaintains the IND/CTA: protocol amendments, CMC amendments, safety reports. Pursues orphan or fast track designations. |
| Phase 2 | ActiveEoP2 meeting, scientific advice, designations, PIP/PSPSecures agreement on the Phase 3 design and CMC plan; agrees the paediatric plan; applies for breakthrough or PRIME if data support it. |
| Phase 3 | ActivePre-NDA/BLA meeting, dossier planningDefines the submission content and format, sets the eCTD plan, negotiates rolling review if available. |
| Submission | LeadingeCTD submission, agency Q&A, labelling negotiationLeads the submission and the review interactions; coordinates responses across functions within tight deadlines. |
| Approval and launch | ActiveLabelling, PMR/PMC tracking, HTA supportFinalises labels, tracks commitments, supports national registrations and pricing dossiers. |
| Post-market | ActiveVariations, sNDA/sBLA, renewals, labelling updatesManages the lifecycle regulatory workload: every manufacturing change and every safety update becomes a submission somewhere in the world. |
Quality
| Stage | What this function is doing |
|---|---|
| Discovery | Not activeNot active in a formal sense; some companies apply research quality standards and data integrity expectations to ELN use. |
| Preclinical | ActiveGLP QAU, first GMP release, QP certification (EU)The GLP quality assurance unit audits tox studies. Quality releases the first clinical batch, approves specifications, and in the EU a Qualified Person certifies the IMP. Vendor qualification of CDMOs and CROs. |
| Phase 1 | ActiveIMP release, deviations, change controlRuns the phase-appropriate quality system: batch release, deviation and OOS handling, change control, supplier oversight. |
| Phase 2 | ActiveQuality system maturation, auditsScales the quality system towards commercial standards; audits CROs and CDMOs; prepares validation master plans. |
| Phase 3 | LeadingValidation oversight, inspection readinessApproves PPQ protocols and reports, method validation, qualification of equipment and facilities; runs mock inspections and data integrity assessments. |
| Submission | LeadingPAI and GCP inspection hostingHosts and manages agency inspections; owns responses to observations (FDA Form 483, EU deficiency letters). |
| Approval and launch | LeadingCommercial QMS, batch certificationOperates the pharmaceutical quality system (ICH Q10): release of every commercial batch, QP certification, complaints, recalls. |
| Post-market | LeadingAPR/PQR, change control, CAPA, audits, recallsSteady-state quality: annual reviews, trend analysis, supplier audits, regulatory intelligence, periodic review of validated systems. |
Manufacturing
| Stage | What this function is doing |
|---|---|
| Discovery | Not activeNot active; CMC development may consult on manufacturability. |
| Preclinical | SupportingPilot or clinical plant, CDMO selectionMakes or contracts the first GMP batch; small companies select a CDMO here. Facility and equipment qualification begins. |
| Phase 1 | SupportingClinical supplySupplies Phase 1 and early Phase 2 from pilot or CDMO capacity. |
| Phase 2 | ActiveCommercial site selection, capacity planningDecides make-or-buy for commercial supply, reserves capacity, plans capital projects for new modalities. |
| Phase 3 | LeadingTech transfer, PPQ batchesReceives the process from development, executes PPQ, builds launch stock. MSAT bridges development and operations. |
| Submission | ActiveLaunch stock, inspectionHosts the PAI, builds inventory, validates shipping and distribution. |
| Approval and launch | LeadingCommercial productionRoutine manufacture at commercial scale; supply chain management; serialisation. |
| Post-market | LeadingRoutine production, CPV, capacity and costContinued process verification, yield improvement, second sourcing, capacity expansion, network changes. |
Safety (tox and PV)
| Stage | What this function is doing |
|---|---|
| Discovery | SupportingEarly safety screeningIn silico and in vitro liability screening (hERG, genotoxicity alerts, off-target panels); exploratory tox to de-risk candidate selection. |
| Preclinical | LeadingGLP toxicology, safety pharmacologyPivotal safety studies that define the starting dose and the safety margins; toxicokinetics; the nonclinical safety sections of the IND. |
| Phase 1 | ActiveSAE and SUSAR management, chronic toxPharmacovigilance sets up the safety database and expedited reporting; toxicology runs longer studies (chronic, reproductive) in parallel with the clinic. |
| Phase 2 | ActiveSafety monitoring, DSUR, carcinogenicity planningAggregate safety review, data monitoring committees, DSUR; carcinogenicity studies (small molecules) start to be ready for filing. |
| Phase 3 | LeadingIntegrated safety analysis, RMPISS, safety narratives, risk management plan, REMS assessment; signal detection at scale. |
| Submission | ActiveSafety updates, RMP negotiation120-day safety update, responses on safety questions, RMP and label safety sections. |
| Approval and launch | ActivePost-marketing surveillance from day oneICSR intake, literature monitoring, QPPV oversight; first PSUR cycle. |
| Post-market | LeadingPSUR/PBRER, signal management, label updatesContinuous surveillance, periodic reports, signal evaluation, label changes, risk minimisation measures, and safety-driven Phase 4 studies. |
Systems / informatics
| Stage | What this function is doing |
|---|---|
| Discovery | SupportingELN, registration, screening data; no formal validationResearch systems (ELN, compound or sequence registration, assay databases, cheminformatics) support IP and reproducibility. Typically not validated; increasingly "verified" for data integrity and FAIR data. |
| Preclinical | ActiveCSV starts: GLP data systems, LIMS and CDS for GMP release, eTMF set-upFirst systems holding regulated records: tox study data capture, bioanalytical LIMS, QC LIMS and chromatography data systems for the first GMP batch, document management for the IND. GAMP 5 risk-based validation, 21 CFR Part 11 and EU Annex 11 controls (audit trails, access, e-signatures). |
| Phase 1 | ActiveEDC, CTMS, safety database, eTMF, IMP labelling and IRTClinical systems go live under GCP: electronic data capture, trial management, randomisation and trial supply (IRT), safety database (for example Argus-type systems), electronic trial master file. |
| Phase 2 | ActiveStability LIMS, ELN in development, statistical software, QMSDevelopment analytical data grows: stability modules, ELN for method development, statistical tools for DoE; electronic QMS for deviations and change control. |
| Phase 3 | LeadingValidated QC systems at commercial site, MES, ERP, SDMSCommercial site systems are validated ahead of PPQ and PAI: manufacturing execution, ERP for materials and batch genealogy, LIMS and CDS in QC, scientific data management for raw data retention, electronic batch records. |
| Submission | LeadingeCTD publishing, RIM, inspection-ready data integrityRegulatory information management and publishing tools; inspection readiness focuses on audit trail review, data integrity assessments and periodic review evidence. |
| Approval and launch | ActiveSerialisation, distribution, PV systems at scaleTrack-and-trace (DSCSA, EU FMD), warehouse and distribution systems under GDP, and the full pharmacovigilance stack (intake, case processing, signal detection). |
| Post-market | ActivePeriodic review, change control, upgrades, data migrationValidated state maintained through periodic review, patch and upgrade management, vendor audits, and data migration when systems are replaced. Lifecycle of the systems mirrors the lifecycle of the product. |